el2535
Stock No : 100-022599
Man No : EL2535
The EL3362-0100 analog input terminal enables the direct connection of resistance bridges (strain gauges) or load cells using the 4-wire or 6-wire terminating system. It processes the ratio of the bridge voltage UDÂ to the supply voltage UREF and outputs the final load value as a process value based on the terminal settings. This enables precise recording of weights, torques, and vibrations with a sampling rate of 10,000 samples per second. The integrated bridge supply is generated from the 24 V of the power contacts.
Stock No : 100-022599
Man No : EL2535
Stock No : 100-022600
Man No : EL2535-0002
Stock No : 100-022601
Man No : EL5042
Stock No : 100-022602
Man No : EL5151